Myco Labs H14 99.995% HEPA Replacement Filter for 2' x 4' Fan Filter Unit (FFU)

$39999
Taxes, discounts and shipping calculated at checkout.


Description

The Myco Labs 2' × 4' H14 HEPA Replacement Filter is the direct-fit filter for the Myco Labs 2' × 4' Fan Filter Unit. Swap it in and your FFU is back to a full 47" stream of clean laminar airflow for agar, liquid culture and inoculation work.

It's rated 99.995% efficient at 0.3 microns for ISO Class 5 / Class 100 clean air, and at 47.1" × 22.9" × 2.95" it's sized to the FFU's filter section, so there's nothing to rebuild.

  • H14 HEPA
  • ISO Class 5
  • Direct fit
  • Tool-free swap
  • 47.1" × 22.9"Filter size
  • 2.95"Thickness
  • 99.995%@ 0.3 microns
  • H14HEPA grade
  • Class 100ISO Class 5

Why replace with the matching filter

Myco Labs 2 x 4 H14 HEPA replacement filter with black face frame and honeycomb face mesh
Same H14 rating

99.995% at 0.3 microns, the same grade your FFU shipped with, so your clean-air rating stays at ISO Class 5.

Myco Labs 2 x 4 fan filter unit on a stainless steel lab bench, showing the latched fan and filter sections
Sized to the 2' × 4' frame

Built to the FFU's filter section. The safety latches pull the fan housing tight to the filter so air goes through the media, not around it.

Labeled diagram of the Myco Labs 2 x 4 FFU showing the intake pre-filter, fan, control box and H14 HEPA filter
Pre-filter protects it

The pre-filter on the fan intake catches dust and larger particles first. Keep it clean and the HEPA holds its airflow longer.

How to swap the filter

No tools needed. Work on a table at least 4' long so you can lay the unit down flat.

1Unplug it

Turn the FFU off, unplug it and lay it down with the filter face up.

2Release the latches

Open the safety latches that join the fan housing to the filter section and lift the old filter out.

3Seat the new filter

Set the new filter in place with the honeycomb face pointing out. Handle it by the frame, never the media.

4Latch and run

Close every latch, plug it in and run it for a few minutes before you start working.

Never wash the HEPA filter. Water and vacuums damage the media and the seal. Keep the intake pre-filter clean instead so dust never reaches the HEPA.

When it's time for a new filter

Myco Labs 2 x 4 replacement HEPA filter dimensions: 47.1 by 22.9 by 2.95 inches, Class 100 / ISO Class 5 47.1" × 22.9" × 2.95"
Check your size before you order

Measure your current filter. If it's 47.1" × 22.9" × 2.95", this is the one. Keeping a spare on hand means a worn filter never stalls a batch of plates or transfers.

  • Airflow drops on the same speed setting
  • Media is torn, wet or damaged
  • Contamination creeping up on clean work
Have a Bonsai 4' × 2' FFU?

This filter fits the Myco Labs unit only. Bonsai FFUs take their own 24" × 48" × 3" filter.

Get the Bonsai 2' × 4' replacement filter instead.

Specifications

Specification Detail
Brand Myco Labs
Filter size 47.1" × 22.9" × 2.95"
Filter type H14 HEPA, honeycomb face mesh
Efficiency 99.995% at 0.3 microns
Clean-air rating ISO Class 5 / Class 100
Rated airflow (in the FFU) 430–1,440 m³/h (about 253–848 CFM), varies with fan speed and operating conditions
Compatible unit Myco Labs 2' × 4' Fan Filter Unit
Care Do not wash or vacuum

Keep your clean bench running

Replacement HEPA Myco Labs 2' × 4' FFU Riser Bonsai Filter
Use it for Restoring airflow Wide bench or 2' × 4' ceiling Lifting work into the airflow Bonsai 4' × 2' FFU
Size 47.1" × 22.9" × 2.95" 47.1" × 22.9" × 11.75" 12" 24" × 48" × 3"
Step Maintenance Clean air source Bench setup Maintenance
Fits Myco Labs 2' × 4' FFU Takes this filter Any FFU or hood Bonsai 4' × 2' only

HEPA filter replacement chart

There's no single expiry date for a HEPA filter. It wears out two ways: dust loading, which tracks run hours and how clean your room is, and aging of the media and gasket seals, which tracks the calendar. Plan on about 24 months for typical hobby use and 12–18 months in a busy lab. Keep it in service as long as it passes an agar plate test and holds its airflow, and replace it sooner if it doesn't.

HEPA filter replacement chart for FFUs and flow hoods: planning hours and calendar months by environment, from dusty 24/7 industrial use at 6–12 months to very light hobby use at 36–48 months

Our HEPA filter replacement guide explains each row of the chart and walks through four simple tests (agar plates, a flame test, an anemometer reading and a pre-filter check) that tell you when your filter is actually done.

FAQ

What units does this filter fit?

It fits the Myco Labs 2' × 4' Fan Filter Unit only. Bonsai FFUs use their own filters, so order the Bonsai replacement filter for your Bonsai unit's size.

What size is the filter?

47.1 × 22.9 inches and 2.95 inches thick. Measure your current filter before ordering.

How do I know it's time to replace it?

When airflow at the filter face drops noticeably on the same speed setting, or the filter media is torn, wet or visibly damaged, it's time for a new one.

Can I wash or vacuum the HEPA filter?

No. Washing or vacuuming damages the media and the seal. Keep the intake pre-filter clean instead so dust doesn't reach the HEPA.

How do I install it?

Unplug the FFU, release the safety latches that join the fan housing to the filter section, swap in the new filter with the honeycomb face pointing out, then re-latch and run the unit for a few minutes before working.

What filtration rating is it?

H14 HEPA, 99.995% efficient at 0.3 microns, for ISO Class 5 / Class 100 clean air.

How often should I replace the HEPA filter?

For typical hobby use, plan on replacing it about every 24 months; in a busy lab running most of the day, every 12–18 months; and in a dusty, round-the-clock space, every 6–12 months. Some manufacturers recommend replacing as often as every 12 months, because filter media and seals age even when the unit isn't running. Treat 24 months as a planning number, and let an agar plate test and an airflow check tell you when it's actually done. Our HEPA filter replacement guide has the full chart and four simple tests.